Home > Components and Spare Parts > EDI
Ionpure LX-HI Instant Hot Water Sanitizable EDI Modules
Ionpure LX-HI Instant Hot Water Sanitizable EDI Modules
IONPURE LX-HI MODULE
Hot water sanitization has been shown to be more effective than chemical sanitization for controlling microbial growth. Ease of operation, maximum reliability and low operating costs are signature features of Ionpure® modules. LX-HI
DETAILS

IONPURE® LX-HI INSTANT HOT WATER SANITIZABLE CONTINUOUS ELECTRODEIONIZATION (CEDI) MODULES


IONPURE LX-HI MODULE 

Hot water sanitization has been shown to be more effective than chemical sanitization for controlling microbial growth. Ease of operation, maximum reliability and low operating costs are signature features of Ionpure® modules. LX-HI modules are ideal for pharmaceutical, biotechnology and other applications where chemical-free, instant hot water sanitization is desired. LX-HI modules produce high-purity water without regeneration downtime.


LX-HI Series Features

• Hot water sanitizable at 185°F/85°C ± 5°C 

• Continuous operation up to 140°F (60°C) 

• US Patented technology for instant hot water capability – no ramp up/down required 

• Higher sanitization pressures 30 psi/2.0 bar 

• Double O-ring seal guarantees leak-free operation 

 • Proven performance after 150+ sanitizations 

• Concentrate recirculation and brine injection not required 

• Wetted materials of construction comply with FDA requirements


OPERATING ENVIRONMENT 

Installation should be indoors with no direct sunlight and should have a maximum ambient room temperature of 113°F (45°C). 


QUALITY ASSURANCE STANDARDS 

CE marked. Each module is factory tested to meet strict industry standards and is manufactured in an ISO9001 and ISO14000 quality and environmental management system.


Feed Water Specifications 

Feed Water Conductivity Equivalent, including CO2 and Silica

< 40µ S/cm

Temperature  

40-140°F (5-60℃)

Inlet Pressure

20-100psi (1.4-7bar)

Maximum Free Chlorine (as Cl)

< 0.02 ppm

Iron (as Fe)

<  0.01 ppm

Manganese (as Mn)

<  0.01 ppm

Sulfide (S- )

<  0.01 ppm

pH

4–11

Total Hardness (as CaCO3)

<  1.0 ppm

Dissolved Organics (TOC as C)

< 0.5 ppm

Silica (SiO2)

<  1.0 ppm

Typical Module Performance

Operating Parameters


Typical Recovery

90 – 95%

Maximum Feed Pressure

100psi (7bar)

DC Voltage

0-600

DC Amperage

0-10

Pressure Drop Range at Nominal Flow

20-30psi (1.4-2.1 bar)

Maximum Feed Temperature

113°F (45°C)

Sanitization Temperature at 30 psi (2.0 bar)

185°F (85°C)

Typical Product Water Quality


Product Conductivity

<0.1µS/cm

Silica (SiO2 ) Removal

90–99%, depending on feed water


ORDERING DETAILS